화학공학소재연구정보센터
학회 한국공업화학회
학술대회 2006년 가을 (11/10 ~ 11/11, 경희대학교(수원캠퍼스))
권호 10권 2호
발표분야 환경에너지
제목 Analysis of direct formic acid fuel cell performances using three electrodes system
초록 In this experiment, Pt wire-inserted three electrode system was applied to the direct formic acid fuel cell(DFAFC) as a new method for simultaneously measuring overpotentials of the two electrodes ; cathode versus DHE and anode versus DHE. The performances of each part of DFAFC were measured with different concentrations of formic acid at different flow rates of gas and fuel, and the tendencies of anode and cathode polarization curves were observed. Furthermore, potential drop occurred due to mass transfer limitation caused by dilute formic acid solution at the anode.
저자 박정우1, 이재광2, 이재영1, 한종희2, 임태훈1
소속 1Fuel Cell Research Center, 2Korea Institute of Science and Technology
키워드 formic acid; three electrode system