화학공학소재연구정보센터
학회 한국화학공학회
학술대회 2004년 가을 (10/29 ~ 10/30, 호서대학교(아산캠퍼스))
권호 10권 2호, p.2175
발표분야 재료
제목 Effects of residence and evacuation time in pulse-CVI of the chamber-shape reactor for the preparation of C/SiC composites  
초록 Manufacturing C/SiC composites from the reaction of methyltrichlorosilane (CH3SiCl3 , MTS) and hydrogen using a pulsed chemical vapor infiltration (pulse-CVI) in a chamber-shape reactor has been studied. Preform used in this study was three-dimensional carbon fiber preform. Experimental parameters were the reactant gas concentration, the gas admission time(ta), the evacuation time(tp) and the number of pulse. In the pulse CVI process, sequential steps of evacuating by-product gas from the pores, instantaneous introduction of reactant gases into the pores and holding the gas for reaction are repeated. By doing so, the reactant gases diffuse far into the preform. Accordingly, this process can have a short operation time with sufficient infiltration into the pores. As the short admission time (ta) prevents from plugging pores, it becomes possible to infiltrate into the preform and fill pores uniformly. The longer the evacuation time (tp) becomes, the more uniformly the deposition in the preform was obtained.  
저자 김인구, 김용탁, 정귀영
소속 홍익대
키워드 CVI; 복합재료; CVD
E-Mail
원문파일 초록 보기