화학공학소재연구정보센터
학회 한국화학공학회
학술대회 2018년 봄 (04/25 ~ 04/27, 창원컨벤션센터)
권호 24권 1호, p.946
발표분야 화학공정안전
제목 휴대용 이온 이동도 탐지장비들의 수포/혼합작용제의 탐지특성 연구Performance test for portable ion mobility spectrometery with various agents conditions(composition, concentration)
초록 Portable ion mobility spectrometry (IMS) devices are widely used in many countries for national security. The main purpose of this devices is confirmation and detection of the CWA(chemical warfare agents) such as Sarin, VX, HD and phosgene. From the 1970s, united states and british insitutes have developed IMS devices and systemized the devices in late 2000s. ROK army also developed the IMS device which is based on Ni63 ionizer source. We evaluated that US, USA and ROK systemized IMS devices in various conditions for HD and mixed agent.  
저자 김종선, 김현정, 박병황
소속 국방과학(연)
키워드 화학공정안전; 화학물질
E-Mail
원문파일 초록 보기