화학공학소재연구정보센터
Journal of Power Sources, Vol.185, No.2, 1272-1272, 2008
Comment on "A strategy of estimating fuel concentration in a direct liquid-feed fuel cell system" [YJ Chiu, HC Lien, journal of Power Sources 159 (2006) 1162-1168]
The strategy for estimating the methanol concentration provided by Chiu and Lien [Y.J. Chiu, H.C. Lien, journal of Power Sources 159 (2006) 1162-1168] overlooks the performance degradation (PD) of a direct methanol fuel cell (DMFC). In addition, the method may not be suitable in practice. (C) 2008 Elsevier B.V. All rights reserved.