화학공학소재연구정보센터
Journal of Membrane Science, Vol.325, No.2, 719-726, 2008
Analysis of fouling potential in the electrodialysis process in the presence of an anionic surfactant foulant
Fouling of ion exchange membranes in an electrodialysis process is highly sensitive to the concentration of a surfactant. To investigate the influence of the fouling on the process performance, an anion exchange membrane was characterized by electrochemical properties as well as physical and chemical properties. The fouling potential was then quantitatively analyzed using the membrane fouling index as a function of the surfactant concentration. It was observed that the fouling mechanism is initiated by the micelle formation. That is, most of SDBS molecules form a fouling layer on the membrane surface at a higher concentration than the critical micelle concentration. Also the SDBS fouling mechanisms caused by the fouling layer were examined by the electrochemical impedance spectroscopy. The equivalent circuits show that the fouling potential of the system was increased by an additional layer, simultaneously increasing the electrical resistance to permeation of ions through the membrane. However, the SDBS fouling on the membrane was a reversible process. (C) 2008 Elsevier B.V. All rights reserved.