Journal of Hazardous Materials, Vol.162, No.1, 180-185, 2009
Removal of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans by three coagulants in simulated coagulation processes for drinking water treatment
Surface water from Guangzhou to which standard polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were added was treated by coagulation with ferric chloride (FC), polyaluminium chloride (PAC), and aluminium sulfate (AS) at optimum removal dosages for nature organic matter(NOM) to assess the polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) removal efficiencies. PCDD/Fs in suspended particulate matter (SPM) and treated water (TW) after coagulation were analysed. Low residual levels of PCDD/Fs were found in treated water after coagulation: 0.8% for FC, 0.9% for PAC, and 3.1% for AS. The removal efficiency calculated using these results was >99% for FC and PAC and 97-98% for AS. Most PCDD/Fs congeners could be removed by the three coagulation processes; the removal efficiency of FC and PAC was similar, and slightly higher than that of AS. The results also demonstrate that coagulation with FC preferentially removed tetra- and penta-substituted PCDD/Fs from raw water. (C) 2008 Elsevier B.V. All rights reserved.
Keywords:Polychlorinated dibenzo-p-dioxins;Polychlorinated dibenzofurans;Removal efficiency;Coagulants;Water treatment