화학공학소재연구정보센터
Desalination, Vol.249, No.1, 212-216, 2009
Evaluation of coagulation and PAC adsorption pretreatments on membrane filtration for a surface water in Korea: A pilot study
Application of membrane filtration has been significantly expanded throughout the world in two decades. A project was launched to facilitate the application of membrane filtration in drinking water plants in Korea in 2004. Five pilot plants each with a capacity of 500 m(3)/d were installed in a Gueui Drinking Water Plant. The Han River water was a main raw water source for the plants. Key parameters of the raw water were examined. The raw water characteristics are tremendously varied with seasons and rain fall, especially in terms of turbidity and algae numbers. The operation of pretreatment was of substantial importance due to the variation of the raw water. Coagulation and powdered activated carbon adsorption were performed as pretreatment options of microfiltration. The coagulant doses were optimized with increasing turbidity compared to the conventionally used operational manual. PAC adsorption was applied to overcome fouling by high algae numbers. The addition of PAC relieved the aggravation of fouling. However, the PAC addition could not stop the undergoing fouling. A set of laboratory experiments showed that the removal of floc aggregates after coagulation and PAC was critical to maintain high water flux in the membrane system. (C) 2009 Elsevier B.V. All rights reserved.