Chemical Engineering Communications, Vol.194, No.10-12, 1596-1607, 2007
Comparison and validation of OHM and SCEM measurements for a full-scale coal-fired power plant
Mercury emission measurements were performed at a 250 M W coal-fired power plant using the Ontario Hydro method (OHM) and semi-continuous emission monitors (SCEM). Flue gas sampling was performed at the inlet of the air preheater and at the outlet of the electrostatic precipitator. The results indicated that there is some agreement between the OHM and SCEM measurements on the total mercury species. However, the SCEM results were not always in good agreement with the OHM measurements on the elemental mercury species. These discrepancies in elemental mercury concentrations are probably the result of the differences in the location of the SCEM and OHM probes, the temperature difference between the SCEM sampling probe and the flue gas, and the nonuniformities in mercury concentration over the flue gas duct cross section. The other factor that contributed to the deviation between the SCEM and OHM measurement results is the sampling method the SCEM measurements were performed at a single point while the OHM probe was traversed over multiple points over the duct cross section and the results were averaged. The effect of the SCEM sampling probe temperature was investigated by designing a sampling probe that could be heated to the sampled flue gas temperatures. This resulted in improvements in the accuracy of the elemental mercury measurements by the SCEM system.
Keywords:activated carbon injection;mercury;mercury measurements;ontario hydro method;semi-continuous mercury monitors