Bioresource Technology, Vol.98, No.2, 266-272, 2007
Packed cage rotating biological contactor system for treatment of cyanide wastewater
The aim of this work was to study the efficiency of the packed cage rotating biological contactor (RBC) system with synthetic wastewater (SWW) containing 800 mg/l BOD5 with various cyanide residue concentrations and hydraulic loading time. The results showed that cyanide had a negative effect to both the system's efficiency and bio-film quality. An increase in cyanide concentration led to a decrease in bio-film growth and the consequent reduction in the removal efficiency of the system. Also, the effluent suspended solids (SS) of the system was increased with increasing cyanide concentrations because the bio-film detached from the media due to the toxicity of the cyanide residue. The system showed the highest COD, BOD5, TKN and cyanide removal efficiencies of 94.0 +/- 1.6%, 94.8 +/- 10.9%, 59.1 +/- 2.8% and 95.5 +/- 0.6%, respectively, with SWW containing 5 mg/l cyanide under HRT of 8 days, while they were only 88.8 +/- 0.7%, 89.5 +/- 0.5%, 40.3 +/- 1.1% and 93.60 +/- 0.09%, respectively, with SWW containing 40 mg/l cyanide. In addition, the effluent ammonia, nitrite and nitrate were increased with increases in cyanide concentration or loading. However, the system with SWW containing the highest cyanide concentration of 40 mg/l showed almost constant COD and BOD5 removal efficiencies of 89% and 90%, even when the system was controlled under the lowest HRT of 8 h. (c) 2006 Elsevier Ltd. All rights reserved.
Keywords:packed cage rotating biological contactor system;rotary biological contactor (RBC);potassium cyanide (KCN);cyanide (CN);bio-film