화학공학소재연구정보센터
Chemical Engineering Science, Vol.61, No.9, 2913-2920, 2006
Design of multiple impeller stirred tanks for the mixing of highly viscous fluids using CFD
The effect of multiple Intermig impeller configuration on hydrodynamics and mixing performance in a stirred tank has been investigated using computational fluid dynamics. Connection between impeller stages and compartmentalisation has been assessed using Lagrangian particle tracking. The results show that by a rotating the Intermig impeller by 45 degrees with respect to its neighbours, instead of a 90 degrees rotation as recommended by manufacturers, enables a wider range of operating conditions, i.e., lower Reynolds number flows, can be handled. Furthermore by slightly decreasing the distance between the lower two impellers, fluid exchange between the impellers is ensured down to Re = 27. (c) 2005 Elsevier Ltd. All rights reserved.