Chemical Engineering Science, Vol.60, No.22, 6085-6093, 2005
Calculation of flow fields in two and three-phase bubble columns considering mass transfer
The dimension of bubble column reactors is often based on empirical correlations. Very popular is the axial dispersion model. However, the applicability of these models is limited to the experimental conditions for which the dispersion coefficients are measured, because backmixing depends strongly on the columns dimension and the flow regime. This paper presents a numerical method for the calculation of the three-dimensional flow fields in bubble columns based on a multi-fluid model. Therefore, the local bubble size distribution is considered by a transport equation for the mean bubble volume, which is obtained from the population balance equation. For comparison with experimental results, the axial dispersion coefficients in the liquid and gas phase are calculated from the instationary, three-dimensional concentration fields of a tracer. The model is then extended to include mass transfer between the gas and liquid phase. Increasing mass transfer rates significantly influence the flow pattern. For several applications, a dispersed solid phase is added. For the calculation of three-phase gas-liquid-solid flow, the solid phase is considered numerically by an additional Eulerian phase. (c) 2005 Elsevier Ltd. All rights reserved.