Thin Solid Films, Vol.468, No.1-2, 222-225, 2004
Reduction of the boron cross-contamination for plasma deposition of p-i-n devices in a single-chamber large area radio-frequency reactor
In this article, a new treatment to reduce boron contamination of the interface between the p- and i- layer is presented. An ammonia flush, performed at 10 Pa for 1 min, after deposition of the p-layer considerably reduces the boron contamination at the p-i interface of amorphous silicon p-i-n solar cells prepared in a single-chamber reactor. This treatment avoids the need to move the substrate out of the reactor during the full deposition process of a solar cell, thereby reducing costs. The measurement of boron contamination depth profile in the i-layer was done by Secondary Ion Mass Spectroscopy and the effectiveness of the treatment was supported by quantum efficiency and I-V measurements of solar cells. (C) 2004 Elsevier B.V. All rights reserved.