International Journal of Heat and Mass Transfer, Vol.46, No.11, 2015-2026, 2003
Cooling of cylindrical vertical tanks submitted to natural internal convection
A numerical and an experimental analysis of velocity and temperature fields inside a storage tank submitted to natural convection is presented. The analysis was performed in two stages. In the first stage, the temperature profile along the vertical axis of the storage tank was obtained experimentally and numerically, for cooling time ranging from 45 to 60 h. The numerical analysis was carried out using a transient bi-dimensional model in cylindrical co-ordinates. In the second stage, after the numerical code validation, 40 cases of cooling with four aspect ratios, five insulation thicknesses, and two different volumes were simulated. In all simulations, thermal losses for the environment in all tank walls (side, top and bottom) were considered. Two correlations for the Nusselt number, encompassing all the forty cases, were obtained with these results. (C) 2003 Published by Elsevier Science Ltd.