International Journal of Heat and Mass Transfer, Vol.46, No.5, 837-849, 2003
Turbulent heat transfer and flow characteristics in a horizontal circular tube with strip-type inserts. Part II. Heat transfer
This paper is the second of two papers that presents the results of an extensive study of turbulent heat transfer and pressure drop in a horizontal tubes with strip-type inserts. Experimental data were taken for air for a class of strip inserts (longitudinal strip and crossed-strip). The insert was characterized by the parameters of 1less than or equal toARless than or equal to5 and R-* (=0.5 and 1). Friction factor data (from Part 1) and temperature measurements were used to understand the underlying physical phenomena responsible for the heat transfer enhancement for 6500less than or equal toReless than or equal to19500. Nusselt numbers were between four and two times the bare tube values at low Re and high Re, respectively. Performance evaluation index R1 (constant pumping power) and R2 (constant heat duty) were made and an optimum condition would be thus found.