Desalination, Vol.150, No.1, 31-43, 2002
A new method of measuring and presenting the membrane fouling potential
The silt density index (SDI) and modified fouling index (MFI) characterisation methods are well known for the evaluation of membrane fouling potential of dispersed particulate matter (suspended solids, colloids) in a feed. The SDI and MFI methods, however, reduce the overall and very complex fouling phenomena into a one number value, on which the interpretation of the fouling potential of the feed is based. Considering such a one number characteristic, a significant amount of information from the fouling measurement (data) is lost. In this paper a concept is introduced in order to preserve such information and supplement the existing indexes. The proposed method measures, processes and presents data in a specific format. To illustrate the concept, some results are shown from measurements on three types of feed. Future systematic research will also include the measurement on some model feeds with, for example, well characterised dispersions for comparison purposes. However, based on the contents of this paper, a discussion on the method could be initiated.