화학공학소재연구정보센터
Biotechnology Progress, Vol.18, No.5, 1047-1053, 2002
Dual excitation ratiometric fluorescent pH sensor for noninvasive bioprocess monitoring: Development and application
The development and application of a fluorescent excitation-ratiometric, noninvasive pH sensor for continuous on-line fermentation monitoring is presented. The ratiometric approach is robust and insensitive to factors such as source intensity, photobleaching, or orientation of the patch, and since measurements can be made with external instrumentation and without direct contact with the patch, detection is completely noninvasive. The fluorescent dye 8-hydroxy-1,3,6-pyrene trisulfonic acid was immobilized onto Dowex strongly basic anion-exchange resin, which was subsequently entrapped into a proton-permeable hydrogel layer. The sensor layer was polymerized directly onto a white microfilfration membrane backing that provided an optical barrier to the fluorescence and scatter of the fermentation medium. The ratio of emission intensity at 515 nm. excited at 468 nm to that excited at 408 nm correlated well with the pH of clear-buffers, over the pH range of 6-9. The sensor responded rapidly (<9 min) and reversibly to changes in the solution pH with high precision. The sterilizable HPTS sensor was used for on-line pH monitoring of an E. coli fermentation. The output from the indwelling sensor patch was always in good agreement with the pH recorded off-line with an ISFET probe, with a maximum discrepancy of 0.05 pH units. The sensor is easily adaptable to closed-loop feedback control systems.