Energy, Vol.19, No.12, 1219-1223, 1994
OPTIMAL PERFORMANCE OF A GEOTHERMAL HEAT-ENGINE-DRIVEN HEAT-PUMP SYSTEM
A geothermal heat-powered, low-temperature Rankine cycle is suitable for the operation of a conventional mechanical compression heat-pump cycle in providing heating and cooling loads. This system is analyzed using a finite-time thermodynamic approach. The only irreversibilities are associated with heat transfer between the system and surrounding thermal reservoirs.