화학공학소재연구정보센터
Chemical Engineering Communications, Vol.183, 39-48, 2000
The improvement of performance in parallel-plate heat exchangers by inserting in parallel an impermeable sheet for double-pass operations
Considerable improvement of heat transfer in flat-plate heat exchangers is obtainable by inserting in parallel an impermeable, resistless sheet to divide an open duct into two channels for double-flow operations. The effect of impermeable-sheet location on the enhancement of transfer efficiency as well as on the increment of power consumption, has been discussion.