Korean Journal of Chemical Engineering, Vol.17, No.5, 502-505, September, 2000
Measurement of Infinite-dilution Activity Coefficients of Alcohols in Water Using Relative Gas-liquid Chromatographic Method
E-mail:
Infinite-dilution activity coefficients of n-alcohols (C-1-C-8) in water were measured by using the relative gas-liquid chromatographic method proposed by Orbey and Sandler [1991]. The temperature range of measurement was 298 to 343 K. The gamma(infinity) values at 298.15 K varied from 1.72 (methanol) to 1970 (n-heptanol). ASOG, UNIFAC, modified UNIFAC (Dortmund). modified UNIFAC (Lyngby) group contribution methods could predict gamma(infinity) to within 16.9, 28.8, 23.9 and 31.8 average percent error, respectively, for all systems and temperatures.
Keywords:Measurement;Infinite-Dilution Activity Coefficients;Relative Gas-Liquid Chromatography;ASOG;UNIFAC
- Butler JA, Ramchandani CN, Thomson DW, J. Chem. Soc., 280 (1935)
- Gmehling J, Li J, Schiller M, Ind. Eng. Chem. Res., 32, 178 (1993)
- Gmehling J, Menke J, Schiller M, "Activity Coefficients at Infinite Dilution C1-C9," DECHEMA Chemistry Data Series, Vol. IX, Part 3, Frankfurt (1994)
- Hansen HK, Rasmussen P, Fredenslund A, Schiller M, Gmehling, Ind. Eng. Chem. Res., 30, 2352 (1991)
- Kojima K, Tochigi K, Seki H, Watase K, Kag. Kog., 32, 149 (1968)
- Larsen BL, Rasmussen P, Fredenslund A, Ind. Eng. Chem. Res., 26, 2274 (1987)
- Ochi K, Kojima K, J. Chem. Eng. Jpn., 20, 6 (1987)
- Orbey H, Sandler SI, Ind. Eng. Chem. Res., 30, 2006 (1991)
- Tochigi K, Tiegs D, Gmehling J, Kojima K, J. Chem. Eng. Jpn., 23, 453 (1990)
- Tsonopoulos C, AIChE J., 33, 263 (1974)
- Uchiyama M, Tochigi K, Kojima K, "Measurement of Infinite Dilution Activity Coefficients of Alcohols in Water Using Relative Gas-Liquid Chromatograph Method," Preprints of 61(st) annual meeting of SCEJ, paper no. G203, Nagoya (1996)