Separation Science and Technology, Vol.30, No.7-9, 1259-1268, 1995
A Simple-Model for Strontium Breakthrough on Zeolite Columns
The Process Waste Treatment Plant (PWTP) at the Oak Ridge National Laboratory is designed to remove radioactive contaminants, principally Sr-90, from process wastewater. Planned upgrades to the PWTP will use chabazite zeolite columns. Pilot-scale studies have shown that mass transfer zone lengths increase from 10 to about 30 cm as the superficial velocity increases from 5.5 to 22 cm/min. Calculations with a multicomponent equilibrium model showed that the distribution coefficient for strontium remains essentially constant over the process conditions, suggesting that a simple kinetic model (the Rosen long-bed solution) should adequately represent breakthrough behavior. Using a distribution coefficient of 4.87 L/g predicted by the equilibrium model, good agreement was found between experimental breakthrough curves and those calculated with the Rosen solution. This model allows prediction of bed depths and cycle times necessary to achieve the required decontamination factor at high zeolite utilization efficiencies over a wide range of flow conditions.