Automatica, Vol.34, No.3, 339-344, 1998
Passivity approach to fuzzy control systems
Fuzzy controllers bring treated as passive dynamic nonlinear controllers, stability of fuzzy control loops is proven with the unique condition that the controlled plant can be made passive by zero shifting. For linear time-invariant plants, this approach leads to frequency response conditions similar to the previous results in the literature, but which are more general and can include robust stability considerations.