Journal of Vacuum Science & Technology B, Vol.13, No.6, 2665-2670, 1995
Alignment Scheme for Through-the-Lens Alignment
A real-time through-the-lens alignment system that locks the mask and wafer together via a feedback system on a deep ultraviolet (DUV) camera is described. The mask can be moved to actively track wafer motions even when the resist is being exposed. In support of this, we have devised a novel, high sample rate alignment system. Bench top experiments have verified the basic principles behind the design, emphasizing the "active" alignment mode. A one-dimensional aligner will be installed on a stepper to test the concept with exposures on silicon wafers. The goal is to produce an alignment system that improves both overlay accuracy and throughput on DUV steppers.