화학공학소재연구정보센터
Renewable Energy, Vol.134, 343-356, 2019
Comparative study of photovoltaic thermal (PVT) integrated thermoelectric cooler (TEC) fluid collectors
In this research, photovoltaic thermal integrated thermoelectric cooler (PVT-TEC) collector has been analyzed, considering three different types of PV modules, namely opaque, semitransparent and Aluminium base. The analysis is based on two models namely, thermal model and artificial neural network (ANN) model. The advantage of ANN model is that it does not require several parameters and complex calculations, unlike thermal model. The performance of opaque PVT-TEC collector [Case 1] has been studied by considering air [Case 1a] and water [Case 1b] as working fluids. The overall electrical efficiency and thermal efficiency of [Case 1b] is greater than [Case 1a] by 1.9-2.8% and 20.8-21.8%, respectively. Also, the impact of base cover material of PV module has been discussed by evaluating and comparing the performances of [Case 1b] opaque PVT-TEC water collector, [Case 2] semitransparent PVT-TEC water collector and [Case 3] Aluminium base PVT-TEC water collector. The results demonstrate that the daily overall electrical energy gain, daily rate of thermal energy gain and daily overall exergy gain is the highest for [Case 3] Aluminium base PVT-TEC water collector. Further, the results calculated from thermal model have been compared with ANN model and a fair agreement has been achieved. (C) 2018 Elsevier Ltd. All rights reserved.