화학공학소재연구정보센터
International Journal of Heat and Mass Transfer, Vol.130, 514-522, 2019
Experimental study of critical heat flux in flow boiling under subatmospheric pressure in a vertical square channel
Critical Heat Flux (CHF) is the maximal limit of heat flux in two-phase nucleate boiling heat transfer; therefore, an understanding of CHF under a wide range of conditions is important for safe system operation. In this work, CHF experiments are conducted over a range of subatmospheric system pressures in a vertical square channel that is heated on one side. The experimental conditions cover a pressure range of 20 kPa to 108 kPa, a mass flux range of 45-190 kg/m(2)-s, and an inlet subcooling range of 0-14 K. Heat flux is gradually increased until an excursion of the wall temperature occurs, indicating CHF. For the experimental conditions considered, CHF increases with rising system pressure, mass flux, and inlet subcooling, although the effects of mass flux and inlet subcooling are weak. A new correlation for CHF is developed and found to predict the data with an average error of +/- 15.6%. (C) 2018 Elsevier Ltd. All rights reserved.