화학공학소재연구정보센터
Journal of Membrane Science, Vol.549, 649-659, 2018
Selective-exhaust gas recirculation for CO2 capture using membrane technology
Membranes can potentially offer low-cost CO2 capture from post-combustion flue gas. However, the low partial pressure of CO2 in flue gases can inhibit their effectiveness unless methods are employed to increase their partial pressure. Selective-Exhaust Gas Recirculation (S-EGR) has recently received considerable attention. In this study, the performance of a dense polydimethylsiloxane (PDMS) membrane for the separation of CO2/N-2 binary model mixtures for S-EGR application was investigated using a bench-scale experimental rig. Measurements at different pressures, at different feeding concentrations and with nitrogen as sweep gas revealed an average carbon dioxide permeability of 2943 +/- 4.1%(RSD) Barrer. The bench-scale membrane module showed high potential to separate binary mixtures of N-2 and CO2 containing 5-20% CO2. The permeability was slightly affected by feed pressures ranging from 1 to 2.4 bar. Furthermore, the separation selectivity for a CO2/N-2 mixture of 10%/90% (by volume) reached a maximum of 10.55 at 1.8 bar. Based on the results from the bench-scale experiments, a pilotscale PDMS membrane module was tested for the first time using a real flue gas mixture taken from the combustion of natural gas. Results from the pilot-scale experiments confirmed the potential of the PDMS membrane system to be used in an S-EGR configuration for capture of CO2.