Energy Conversion and Management, Vol.157, 266-276, 2018
Exergetic and thermoeconomic analysis of a trigeneration system producing electricity, hot water, and fresh water driven by low-temperature geothermal sources
Performance of a small-scale trigeneration system driven by low-temperature geothermal sources for producing fresh water, heating (hot water) and electricity is investigated from thermodynamic and economic standpoints. This system, utilizing a single stage absorption heat transformer leads to an increase in heat source temperature to be used in single stage evaporation desalination process and also providing water heating. Furthermore, an organic Rankine cycle is used for electric power generation. The developed model is validated with available data and effects of decision variables namely geothermal source, absorber and condenser temperatures on energy and exergy efficiencies of the overall system, power to water ratio and levelized cost of energy (LCOE) are investigated. The findings show that the increase in absorber and condenser temperatures leads to lower energy and exergy efficiencies, and higher LCOE and these effects are more significant at lower geothermal temperatures. Moreover, it is estimated that LCOE of proposed system is by far lower than that of a sole ORC powered with low geothermal water sources, whereas levelized cost of water (LCOW) is just comparable with small-scale membrane desalination processes. Utilizing a 100 degrees C geothermal water, the proposed system has a production capacity of 0.662 kg/s fresh water, 161.5 kW power, and 246 kW heat load.
Keywords:Trigeneration;Low-temperature geothermal;Thermoeconomic;Absorption heat transformer;Desalination;Organic Rankine cycle (ORC)