화학공학소재연구정보센터
Separation and Purification Technology, Vol.187, 334-342, 2017
Humic acid removal from micro-polluted source water in the presence of inorganic salts in a gas-phase surface discharge plasma system
Humic acid (HA), a predominant type of natural organic matter in surface water, had several potential environmental and health risks. A gas phase surface discharge plasma system was employed to eliminate HA from micro-polluted surface water, and the effects of some concomitant inorganic ions on HA removal were evaluated. The experimental results showed that approximately 89.4% of HA could be smoothly eliminated after 40 min of the discharge plasma treatment, and the HA removal process could be fitted well by the first-order kinetic model. The presence of anions such as CO32- and Cl- in the natural water were adverse for the HA removal due to their competition for the active species, whereas the effects of NO3- and SO42- on the HA removal could be neglected; this deduction was also confirmed via the evolution of fluorescence spectra intensity of center dot OH radicals. Although Cu2+ could react with H2O2 via Fenton-like reaction, its presence was still adverse for the HA removal due to the complexing effect of Cu2+ with HA molecules. In addition, the HA removal processes were characterized by UV-Vis spectrum, DOC removal, specific absorbance parameters, and three-dimensional fluorescence spectrum analysis. (C) 2017 Elsevier B.V. All rights reserved.