Experimental Heat Transfer, Vol.30, No.6, 544-562, 2017
Effect of impingement jet on the full-coverage film cooling system with double layered wall
The present study was conducted to evaluate the total cooling effectiveness in combined full-coverage film cooling and impingement jet using an infrared thermographic technique. The effect of film cooling hole angle, blowing ratio, and height to diameter ratio between the film cooling and impingement jet plates was discussed. The total cooling effectiveness increased as impingement jet cooling was added. The angled film cooling holes had approximately 4.6% higher total cooling effectiveness than the normal film cooling holes. The total cooling effectiveness was almost constant regardless of height to diameter ratio, but enhanced as the blowing ratio was increased.
Keywords:gas turbine;double wall cooling;full-coverage film cooling;array impingement jet;total cooling effectiveness