화학공학소재연구정보센터
Process Safety and Environmental Protection, Vol.105, 12-20, 2017
Statistical optimization of electrochemical oxidation of ethylene glycol using response surface methodology
Large amounts of ethylene glycol (EG) based antifreeze liquids are daily discharge into the receiving waters. The chemical oxygen demand (COD) detected in most of the lakes and rivers close to the discharge points exceeded 100,000 mg O-2/L. With such an amount, biological and chemical processes are inefficient to completely remove EG. In order to efficiently remove EG, electrochemical oxidation (ECO) of EG was carried out. Niobium Boron Doped Diamond (Nb/BDD) was used as anode whereas carbon felt was used as cathode. Different operating parameters including current intensity, treatment time, electrolyte concentration and pollutant concentration were tested. The application of 0.077 A/cm(2) of current density during 120 min in the presence of 7.0 g/L of Na2SO4 allowed 89.6 +/- 0.2% of COD removal with 490 mg O-2/L of residual COD. This result was far below the legislation standard set by the province of Quebec that allows the discharge of 800 mg O-2/L of COD. The efficiency of ECO process was attributed to both direct and indirect oxidation that generate strong oxidizing species (OH degrees, S2O82-, H2O2, etc.) capable of oxidizing organic matters on the surface of the anode and in the bulk of the solution. (C) 2016 Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.