Safety and kinetic parameters analysis for 1,1,-Di(tert-butylperoxy) cyclohexane mixed with monoammonium phosphate
Runaway reactions by organic peroxides have occurred throughout the world. In this study, we used 1,1,Di(tert-butylperoxy) cyclohexane (CH) 70 mass% as the main material, which was extensively employed as initiator for styrene in polymerization. Fire extinguishers are the first fire-fighting apparatus when fires occur. If a fire extinguisher has sat idle for a long time, which would cause the extinguishing agent to damp, it cannot achieve the desired effect and be properly handled at the start of the accident, thereby causing more casualties and property losses. CH 70 mass% was employed to mixed with monoammonium phosphate (MAP) for understanding the phenomenon by applying differential scanning calorimetry (DSC). Safety parameters also were carried out for more deeply understanding the basic characteristics for preventing an accident from occurring, in terms of applying CH 70 mass% as the initiator in the manufacturing process. (C) 2015 Elsevier Ltd. All rights reserved.