Energy, Vol.87, 425-434, 2015
A comparative study on the ammonia-water based bottoming power cycles: The exergoeconomic viewpoint
A comparative exergoeconomic assessment is reported for Ammonia-Water Rankine (AWR) and Ammonia-Water Recuperative Rankine (AWRR) bottoming power cycles. Through investigating temperature distributions of hot and cold fluids and pinch point location in heat exchangers, first energy and exergy analysis is performed and then cost balances and appropriate auxiliary equations are developed for components, so exergoeconomic variables are quantified. A parametric study is also performed to examine the effects on exergoeconomic performance of the cycles, of turbine inlet pressure and ammonia mass fraction in the working fluid. As a result, unit cost of electricity produced by turbine is determined to be 11.87 and 13.85 cent/kWh for the AWR and AWRR systems, respectively. Based on these values it is interesting to note that, unlike the energy and exergy analysis, the exergoeconomic viewpoint prefers the AWR system to AWRR. Also parametric study revealed that ammonia concentration has a great effect on exergoeconomic performance of the both systems. Increasing ammonia mass fraction increases total exergy destruction cost rate as well as unit cost of electricity produced by turbine in the both AWR and AWRR systems. This shows the advantage of using a binary mixture such as ammonia water as a working fluid in these cycles. (C) 2015 Elsevier Ltd. All rights reserved.
Keywords:Exergy;Exergoeconomics;Rankine cycle;Ammonia-water mixture;Ammonia concentration;Low temperature heat source