Journal of Food Engineering, Vol.33, No.1, 181-192, 1997
An application of magnetic resonance imaging to the real time measurement of the change of moisture profile in a rice grain during boiling
The change of moisture distribution in a rice grain during boiling was observed in real-time by NMR T-2 imaging. A series of one-dimensional proton images along a lateral line (through the cross section) perpendicular to the long axis of the grain was obtained every two minutes using a CPMG multi-spin-echo method. The series of images was analyzed to give the apparent T-2 profile, which was then converted into the moisture content profile. The rise in moisture profile during boiling obtained by real-time observation was found to be unexpectedly rapid when it was compared with that reported previously using a non-real-time method for samples which were quenched after boiling for selected periods of minutes. The error in the NMR imaging method caused by the effect of diffusion on the apparent T-2 was fully analyzed using the pictorial phase diagram method.