화학공학소재연구정보센터
Chemical Engineering Research & Design, Vol.92, No.11, 2568-2574, 2014
Co-oxidation of ammonia and isopropanol in supercritical water in a tubular reactor
Improvements in the ammonia removal were only appreciated with the lowest IPA/NH3 molar ratios (0.125 and 0.25) while the oxygen ratio did not have significant influence in the ammonia removal. Nevertheless, a direct relation between the nitrate concentration and the oxygen in excess was found. Nitrate concentration was also found to increase when the IPA/ammonia ratio increased. (C) 2014 The Institution of Chemical Engineers. Published by Elsevier B.V. All rights reserved.