화학공학소재연구정보센터
Chemical Engineering and Processing, Vol.85, 227-240, 2014
Numerical simulation of mixing at 1-1 and 1-2 microfluidic junctions
Computational fluid dynamics (CFD) simulations are carried out to evaluate mixing in different types of 1-1 and 1-2 microfluidic junctions. Computational approach adopted in the study is validated by comparing its predictions with theoretical and experimental results. Asymmetric microfluidic junctions are found to show better mixing than symmetric microfluidic junctions. Among asymmetric microfluidic junctions, mixing is found to improve with increasing skewness of the junction. A new 1-1 microfluidic junction named as OA 10(0)-20(0) W-junction is found to give the best mixing among all 1-1 microfluidic junctions evaluated in this study. Based on this new 1-1 microfluidic junction, several 1-2 microfluidic junctions are conceptualized. Among these 1-2 microfluidic junctions a junction named as 10(0)-20(0)-165(0) WY-junction is found to give the best mixing. Different approaches to improve microfluidic mixing viz simple-junction-complex-layout, complex-junction-simple-layout and complex-junction-complex-layout, are compared. (C) 2014 Elsevier B.V. All rights reserved.