Journal of Electroanalytical Chemistry, Vol.367, No.1-2, 31-40, 1994
A New-Type of Piezoelectric Detector in Liquid .3. Computation of Equivalent-Circuit Parameters of a Piezoelectric Crystal with Separated Electrode and Series Piezoelectric Sensors in Electrolyte Solution
The equivalent circuit parameters of a piezoelectric cyrstals with a separated electrode and a series conductivity electrode in an electrolyte solution were derived on the basis of an improved model. The influences of the specific conductivity, density and viscosity of the electrolyte solution together with the cell constant of the sensors on the equivalent circuit parameters were examined.