Solar Energy, Vol.84, No.4, 710-714, 2010
Optimization and life-cycle cost of health clinic PV system for a rural area in southern Iraq using HOMER software
This paper addresses the need for electricity of rural areas in southern Iraq and proposes a photovoltaic (PV) solar system to power a health clinic in that region. The total daily health clinic load is 31.6 kWh and detailed loads are listed. The National Renewable Energy Laboratory (NREL) optimization computer model for distributed power, "HOMER," is used to estimate the system size and its life-cycle cost. The analysis shows that the optimal system's initial cost, net present cost, and electricity cost is US$ 50,700, US$ 60,375, and US$ 0.238/kW h, respectively. These values for the PV system are compared with those of a generator alone used to supply the load. We found that the initial cost, net present cost of the generator system, and electricity cost are US$ 4500, US$ 352,303, and US$ 1.332/kW h, respectively. We conclude that using the PV system is justified on humanitarian, technical, and economic grounds. (C) 2010 Published by Elsevier Ltd.
Keywords:Photovoltaics (PV);Stand-alone system;Rural electrification;Rural area in Iraq;System;Design