Journal of Loss Prevention in The Process Industries, Vol.26, No.1, 91-95, 2013
Influence of coal particles on methane/air mixture ignition in a heated environment
The temperature at which coal dust glows is normally much lower than the auto-ignition temperature (AIT) of methane/air mixtures, and thus a better understanding is needed regarding methane/air ignition in a heated environment in the presence of coal particles. A horizontal tube apparatus was used to test the effect of brown coal and two kinds of bituminous and anthracite on methane/air combustibility. For the four coal samples tested, the presence of coal particles significantly reduced the minimum temperature for ignition of methane/air mixtures in a heated environment. No. 1 bituminous coal with 12 mm diameter decreased the ignition temperature value from 595 to 500 degrees C. It is thought that pre-ignition of low-AIT volatiles emitted from the heated coal particles ignited the methane/air mixtures. Volatiles, sulfur content, and large porosity of piled coal particles all enhanced ignition of methane/air mixtures in a hot environment, while water content and small particle size reduced ignition. For anthracite, no ignition occurred when temperatures of the heated environment were lower than the AIT of methane (595 C), except for the 12-mm-diameter sample. Anthracite did not readily ignite methane/air mixtures and the ignition mechanism was somewhat similar to that of a burning cigarette. (C) 2012 Elsevier Ltd. All rights reserved.