Journal of Loss Prevention in The Process Industries, Vol.19, No.2-3, 154-160, 2006
Initiation of dust explosions by electric spark discharges triggered by the explosive dust cloud itself
An investigation of ignition of dust clouds by the use of electric spark discharges triggered by the explosive dust cloud itself has been conducted. This method of triggering capacitive sparks probably represents a realistic mechanism for initiating accidental dust explosions in industrial practice. Unlike the conventional method for determining the minimum ignition energy (MIE) in the laboratory, the delay between dust dispersion and spark discharge is not a degree of freedom. In stead, the transient dust cloud itself is used to initiate spark breakdown between electrodes set at a high voltage lower than breakdown in pure air. In the present study, different kinds of dusts were tested as 'spark triggers', and they exhibited quite different abilities to trigger breakdown. Large particles were found to initiate breakdown at lower voltages than smaller ones. In general, conductive particles were not found to initiate breakdown at lower voltages than dielectric ones when using the same dust concentration. Minimum ignition energies (MIE) of three dusts (Lycopodium clavatum, sulphur and maize starch) were determined using the authors' method of study. The MIEs were somewhat higher than those obtained using conventional methods, but relatively close to the values obtained through conventional methods. (c) 2005 Elsevier Ltd. All rights reserved.