화학공학소재연구정보센터
International Journal of Hydrogen Energy, Vol.37, No.8, 6808-6817, 2012
Maximizing the efficiency of a HT-PEMFC system integrated with glycerol reformer
The efficiency and output power density of an integrated high temperature polymer electrolyte fuel cell system and glycerol reformer are studied. The effects of reformer temperature, steam to carbon ratio (S/C), fuel cell temperature, and anode stoichiometric ratio are examined. An increase in anode stoichiometric ratio will reduce CO poisoning effect at cell's anode but cause lower fuel utilization towards energy generation. High S/C operation requires large amount of the energy available, however, it will increase anode tolerance to CO poisoning and therefore will lead to enhanced cell performance. Consequently, the optimum gas composition and flow rate is very dependent on cell operating current density and temperature. For example, at low current densities, similar efficiencies were obtained for all the S/C ratio studied range at cell temperature of 423.15 K, however, at cell temperature of 448.15 K, low S/C ratio provided higher efficiency in comparison to high S/C ratio. High S/C is essential when operating the cells at high current densities where CO has considerable impact on cell performance. Optimal conditions that provide the maximum power density at a given efficiency are reported. Copyright (C) 2012, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.