화학공학소재연구정보센터
Fuel Processing Technology, Vol.106, 84-94, 2013
Distribution of the coal flow in the mill-duct system of the As Pontes Power Plant using CFD modeling
The efficiency of a Power Plant is affected by the distribution of the pulverized coal within the furnace. The coal, which is pulverized in the mills, is transported and distributed by the primary gas through the mill-ducts to the interior of the furnace. This is done with a double function: dry and enter the coal by different levels for optimizing the combustion in the sense that a complete combustion occurs with homogeneous heat fluxes to the walls. The mill-duct systems of a real Power Plant are very complex and they are not yet well understood. In particular, experimental data concerning the mass flows of coal to the different levels are very difficult to measure. CFD modeling can help to determine them. An Eulerian/Lagrangian approach is used due to the low solid-gas volume ratio. (c) 2012 Elsevier B.V. All rights reserved.