Energy, Vol.58, 606-616, 2013
New calculation method for thermodynamic properties of humid air in humid air turbine cycle - The general model and solutions for saturated humid air
The article proposes a new calculation method for thermodynamic properties (i.e. specific enthalpy, specific entropy and specific volume) of humid air in humid air turbine cycle. The research pressure range is from 0.1 MPa to 5 MPa. The fundamental behaviors of dry air and water vapor in saturated humid air are explored in depth. The new model proposes and verifies the relationship between total gas mixture pressure and gas component pressures. This provides a good explanation of the fundamental behaviors of gas components in gas mixture from a new perspective. Another discovery is that the water vapor component pressure of saturated humid air equals P-S, always smaller than its partial pressure (f.P-S) which was believed in the past researches. In the new model, "Local Gas Constant" describes the interaction between similar molecules. "Improvement Factor" is proposed for the first time by this article, and it quantitatively describes the magnitude of interaction between dissimilar molecules. They are combined to fully describe the real thermodynamic properties of humid air. The average error of Revised Dalton's Method is within 0.1% compared to experimentally-based data. (C) 2013 Elsevier Ltd. All rights reserved.