Applied Surface Science, Vol.271, 271-275, 2013
Effects of sealing treatment on corrosion resistance and degradation behavior of micro-arc oxidized magnesium alloy wires
The effects of three different sealing treatments on micro-arc oxidized (MAO) medical magnesium alloy wires using boiling water, zirconia sol-gel, and organic gelatin-hydroxyapatite (HA) coatings on the surface morphology, corrosion resistance, and degradation behavior in simulated body fluid (SBF) and simulated intestinal fluid (SIF) are investigated. The treatments involving boiling water or gelatin-HA coating can effectively seal the discharge channels making the surface pores less and smaller. The treatments also improve the corrosion resistance of the MAO magnesium alloy wires, especially the samples with the gelatin-HA coatings which also exhibit reduced degradation in both simulated physiological environments. (C) 2013 Elsevier B.V. All rights reserved.