화학공학소재연구정보센터
International Journal of Coal Geology, Vol.88, No.4, 227-231, 2011
Time series analysis of CO concentrations from an Eastern Kentucky coal fire
Coal fires in natural outcrops, in abandoned and active coal mines, and in coal and coal-refuse piles are responsible for the uncontrolled emissions of gases, including CO, CO(2), H(2)S, hydrocarbons, and volatile aromatics. Typically, measurements of gases at a mine vent are made over a short time interval, perhaps no more than 10 min, including the time for replicate measurements. Such timing provides little information on longer-term variations in emissions, although comparisons of seasonal measurements suggest such changes do occur. To address this problem, we placed temperature and CO data loggers in coal fire vents to collect time series measurements for a period of up to three weeks. For one experiment, 11 days of data at one-minute intervals indicated that the CO emissions were generally in the 400-550 ppmv range. However near daily depressions in CO concentrations occurred and in some cases fell below 50 ppmv; followed by an increase to similar to 700-800 ppmv; in turn followed by a return to the ambient conditions. Data for a separate 21-day collection period in a different vent of the same fire exhibited similar trends, albeit at a higher CO concentration. The drop in CO concentration may be associated with a meteorologically-driven inhalation cycle of the fire, whereby air diluted the combustion generated CO. We propose this was followed by an increase in the intensity of the fire due to increased O(2) from the inhaled air, producing increased CO concentrations, before settling back to the ambient conditions. (C) 2011 Elsevier B.V. All rights reserved.